Four-phase rhinomanometry: a multicentric retrospective analysis of 36,563 clinical measurements

2015

Rhinomanometry can still be considered as the standard technique for the objective assessment of the ven- tilatory function of the nose. Reliable technical requirements are given by fast digital sensors and modern information technology. However, the xyimaging of the pressure-flow relation typically shows loops as a sign of hysteresis, with the need for resolution of the breath in four phases. The three pillars of 4-phase rhinomanometry (4PR) are the replacement of estimations by measurements, the introduc- tion of parameters related to the subjective sensing of obstruction, and the graphical information regarding the disturbed function of the nasal valve. In a meta-analysis of 36,563 clini…

AdultPercentilemedicine.medical_specialtyVisual Analog ScaleEffective resistanceVisual analogue scaleParameterNoseLogarithmic transformationWhite PeopleXylometazoline03 medical and health sciences0302 clinical medicineStatisticsRetrospective analysismedicineHumans030223 otorhinolaryngologyNosePain MeasurementRetrospective Studiesmedicine.diagnostic_testbusiness.industryAirway ResistanceImidazolesClinical validationGeneral MedicineRhinologyStandard techniqueRhinomanometryNasal DecongestantsMeta-analysismedicine.anatomical_structureOtorhinolaryngologyOtorhinolaryngology030220 oncology & carcinogenesisFour-phase rhinomanometryRegression AnalysisRhinomanometryNasal Obstructionbusinessmedicine.drugEuropean Archives of Oto-Rhino-Laryngology
researchProduct

Tehnisko kļūdu novērtēšana un izskaušana rinomanometrijā

2016

KOPASAVILKUMS Ievads: Jaunas metodes tiek ieviestas, lai rastu vienkāršākus un ātrākus risinājumus spiediena caurules fiksācijai rimomanometrijā. Svarīgi ir pētīt ietekmes uz gaisa plūsmu, lai izvairītos no kļudainiem mērījumiem. Ar datorprogrammu saistītā rinomanometrija pamazām tiek aizstāta ar PNIF ierīci, jo tā ir lētāka un vieglāka lietošanā, līdz ar to ir svarīgi vispirms novērot korelāciju starp abām metodēm. Mērķis: Diplomdarba mērķis bija apzināties un piefiksēt kļūdas un sarežģījumus, kādi rodas veicot četru fāzu rinomanometriju, izmantojot dažādas spiediena caurulītes piestiprināšanas metodes. Vēlviens uzdevums bija apzināties un piefiksēt kļūdas, kas rodas PNIF testa procesā, kā…

Four-Phase Rhinomanometry(4PR)Fixation of pressure tubePNIFPeak Nasal Inspiratory FlowMedicīna